The Sentry Xpress 4.0 micro processor is manufactured by the
Orton Ceramic Foundation and displays the CE mark.
Hr./Min.
When Lit
HIGHER
°C
°F
When Off
When Lit
START/
STOP
LOWER
Program
Review
Run
MICRO PROCESSOR
TM
SENTRYXpress
4.0
Enter
Program
Skip Seg.
Add Hold
Change Temp.
T/C Offset
Alarm
Delay
Review
1
START/STOP Key
Starts and stops a firing.
Press after each
programming step. It works like the
Enter key on a computer.
Down Arrow Key
From press
.Theprogram
you have selected will ap-
pear one step at a time.
When appears,
press .Page4
From
press .
Enter delay time. Press
.Page4
During firing, press
. The program you
entered will appear one
step at a time. Page 4
Indicator
Lights
Temperature Display
Tempera
-
ture display is in °F.
Temperature display is in °C.
Seepage13forinstructions
on selecting °F and °C.
Time Display
:Sepa-
rates hours from minutes. Ex-
ample: Display shown above
is 1 hour and 30 minutes.
°C Display Dot
Cone Fire/Ramp-Hold Version
°F
°C
Sentry Xpress
Digital Temperature Controller
IM-222/5-11
Light is
on during pro
-
gramming.
Light is
on during pro
-
gram review.
Light
blinks during firing.
Up Arrow Key
From
press .Press
to select Cone-Fire or
Ramp-Hold. Pages 6, 8
During a
Ramp-Hold firing, press the
. will appear. Press
. The current segment
ramp or hold number will ap
-
pear. To skip, press
again. Page 10
During a
Ramp-Hold firing, press
repeatedly until ap
-
pears. Press .Eachtime
you press the ,the
hold time for the current seg
-
ment will increase by 5 minutes.
Then press .
Page 10
During a Ramp-Hold firing,
press repeatedly until
appears. Press .
Use the arrow keys to change
the target temperature for the
current segment. Then press
.Page10
During a fir
-
ing, press repeatedly
until appears. Press
. Use the arrow keys to
change the alarm temperature.
Press .Tosilencethe
alarm, press any key. Page 10
At the display,
press . will ap
-
pear. Use arrow keys to adjust
the controller to fire hotter or
cooler. Press to return to
.Page13
*These features are new with the Sentry Xpress 4.0. This manual,
nevertheless, is backward compatible with earlier controllers.
Vue de la page 0
1 2 3 4 5 6 ... 19 20

Résumé du contenu

Page 1 - Sentry Xpress

The Sentry Xpress 4.0 micro processor is manufactured by theOrton Ceramic Foundation and displays the CE mark.Hr./Min.When LitHIGHER°C°FWhen OffWhen L

Page 2 - Introduction

10 Cone-Fire / Ramp-HoldEditing the TargetTemperatureWhile the kiln is firing, you can change the target tem-perature. You can edit only the segment t

Page 3 - Guidelines

11Segment 3 lowers temperature to 800°F / 426°C, the typi-cal casting temperature for silver. (Most types of gold castat 900°F / 482°C.)Note: Casting

Page 4 - 4 Cone-Fire / Ramp-Hold

12 Cone-Fire / Ramp-HoldTo return to from an FE codeTrypressingany key. If that doesn’t work, turn thepoweroff for 10 seconds. Call the factory if the

Page 5 - Cone-Fire

13PF 3 / Power FailureThe powerfailedduring firing and temperaturedroppedmore than 72°F / 40°C by the time the power came back on.The kiln will not re

Page 6 - Cone-Fire Hold

Cone-Fire Schedules - °FSelecting a Fast speed in Cone-Fire increases the segment rates shown in this chart by 20%. Selecting a Slow speed de-creases

Page 7 - Ramp-Hold

15Cone-Fire Schedules - °CSelecting a Fast speed in Cone-Fire increases the segment rates shown in this chart by 20%. Selecting a Slow speed de-crease

Page 8 - Ramp-Hold Programming

16 Cone-Fire / Ramp-HoldTemperature Equivalents ForOrton Self-Supporting Pyrometric Cones°FCone Self-Supporting Cones Pre-FireNum-ber ColorHeated at:

Page 9

17DisplayMessagesThe firing was stopped.(Page 10) Ready for you to enter an alarm temper-ature. When the kiln reaches that temperature, the alarmwill

Page 10 - Features

18 Cone-Fire / Ramp-Holdfacing you. Plug the kiln back in. Touch voltmeter probes(in AC mode) to both INPUT connections (the white andorange wires).CA

Page 11 - Lost Wax

19IndexAbrt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Add Hold Time. . . . . . . . . . . . . . . . . . . . .

Page 12 - Error Messages

2 Cone-Fire / Ramp-HoldContentsGeneral Guidelines . . . . . . . . . . . . . . . . . 3Time and Temperature Displays . . . . . . . . . . . . . . . . . .

Page 13 - °C Display

20 Cone-Fire / Ramp-HoldShorthand InstructionsThese instructions may be confusing until you have read more detailed instructions on Cone-Fire, page 6,

Page 14 - Cone-Fire Schedules - °F

3GeneralGuidelinesTime and TemperatureDisplaysCenter Dot: TimeA center dot appears dur-ing time display. It separateshours from minutes (Exam-ple: 1 h

Page 15 - Cone-Fire Schedules - °C

4 Cone-Fire / Ramp-HoldPower FailuresAfter a power failure, the controller will continue firingprovided that:IThe kiln temperature is above 212°F / 10

Page 16 - Temperature Equivalents For

5We suggest using the witness cone to trouble shoot prob-lems with the ware. If china paints appear faded and yoususpect it is due to over-firing, tes

Page 17 - Trouble Shooter

6 Cone-Fire / Ramp-HoldCone-Fire ProgrammingInstructionsFrom , press (the left button).Using the key (not the ),skip past and se-lect . Then press .Th

Page 18 - Problem: Kiln switch box ½

7Ramp-HoldModeTheory of OperationThe temperature you are firing to is called the targettemperature. After the controller reaches the target tem-peratu

Page 19 - Problem: The kiln overfires